Back to the last certificates list

 Date created 2019-04-04
 Manufacturer JACKON INSULATION GmbH
Ritzlebener Strasse 1
D-39619 ARENDSEE
Germany
 Certificate no. 19/074/1357
 Family Extruded polystyrene (XPS)
 Commercial brand(s) (products)
Products Purposes
JACKODUR KF 300 Feintoleranz
 Plant(s) Arendsee - Allemagne
 Certified thermal conductivity
Thicknesses
mm
Thermal conductivity
λD W/(m.K)
from 20 to 60  mm 0.034 W/(m.K)
from 64 to 180  mm 0.035 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
20 mm 0.55
22 mm 0.60
23 mm 0.65
25 mm 0.70
27 mm 0.75
28 mm 0.80
30 mm 0.85
32 mm 0.90
33 mm 0.95
35 mm 1.00
37 mm 1.05
39 mm 1.10
40 mm 1.15
42 mm 1.20
44 mm 1.25
45 mm 1.30
47 mm 1.35
49 mm 1.40
50 mm 1.45
52 mm 1.50
54 mm 1.55
56 mm 1.60
57 mm 1.65
59 mm 1.70
60 mm 1.75
64 mm 1.80
66 mm 1.85
68 mm 1.90
69 mm 1.95
70 mm 2.00
72 mm 2.05
75 mm 2.10
76 mm 2.15
78 mm 2.20
80 mm 2.25
85 mm 2.40
90 mm 2.55
95 mm 2.70
100 mm 2.85
105 mm 3.00
110 mm 3.10
115 mm 3.25
120 mm 3.40
125 mm 3.55
130 mm 3.70
135 mm 3.85
140 mm 4.00
145 mm 4.10
150 mm 4.25
155 mm 4.40
160 mm 4.55
165 mm 4.70
170 mm 4.85
180 mm 5.10
 Euroclass(es) Euroclasse E

 Other certified characteristics

 Thickness tolerance T3
 Compressive stress (20 mm) CS(10\Y)200
 Compressive stress (30-180 mm) CS(10\Y)300
 Deformation under defined compressive load and temperature conditions DLT(2)5
 Dimensional stability under defined temperature and humidity conditions DS(70,90)
 Water vapor permeability MU50
 Traction perpendicular to the surfaces TR600