Back to the last certificates list

 Date created 2024-05-22
 Holder URSA IBERICA AISLANTES S.A
Paseo Recoletos, 3
E-28004 MADRID
Spain
 Certificate no. 02/020/042/19
 Family Glass wool (MW)
 Commercial brand(s) (products)
Products Purposes
F-Essentia 32 PP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-Essentia 32 QP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-LAINE VERRE 32 PP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-LAINE VERRE 32 QP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-P1052 - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-PRK 32 Roulé - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-PRK 32 - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-URSA Home 32 QP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-URSA Home 32 PP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-URSA THERMOCOUSTIC 32 QP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-URSA THERMOCOUSTIC 32 PP - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-Mur 32 Panneau Kraft - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
F-Mur 32 Rouleau Kraft - Attic insulation by panels or rolls of manufactured mineral wool
- Counter-partition in masonry of small elements
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Plaster tile counter-partition
 Plant(s) El Pla de Santa Maria - Espagne
 Isolant semi-rigide de 45 à 160  mm
 Certified thermal conductivity λD = 0.032 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
45 mm 1.40
50 mm 1.55
55 mm 1.70
60 mm 1.85
75 mm 2.30
80 mm 2.50
85 mm 2.65
90 mm 2.80
100 mm 3.10
101 mm 3.15
110 mm 3.40
120 mm 3.75
130 mm 4.05
140 mm 4.35
150 mm 4.65
160 mm 5.00
All resistances
 Euroclass(es) Euroclasse F
 Other certified characteristics
Characteristic Value
Thickness tolerance T3
Short-term water absorption by partial immersion WS