Back to the last certificates list

 Date created 2018-11-06
 Holder URSA France SAS
Maille Nord III
7 Porte de Neuilly
93160 NOISY LE GRAND
France
 Certificate no. 02/083/022/11
 Family Glass wool (MW)
 Commercial brand(s) (products)
Products Purposes
P-ESSENTIA 38 PN - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-ESSENTIA 38 RN - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-MNU 38 - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-P0051 - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-PNU 38 - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-URSA HOME 38 PN - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-URSA HOME 38 RN - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-URSA THERMOCOUSTIC 38 PN - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
P-URSA THERMOCOUSTIC 38 RN - Insulation on floors of lost lofts
- Insulation between wood floor joists
- Counter plaster wallboard (45 à 150 mm)
- Against masonry wall or plaster tiles (45 à 150 mm)
- Insulation with ventilated cladding (45 à 150 mm)
- Insulation for walls covered with thin stone plates (45 à 150 mm)
- Double masonry wall (45 à 150 mm)
- Wood frame walls (45 à 150 mm)
- Metal double-skinned cladding (45 à 150 mm)
- Distributing or separating partitions between rooms (45 à 150 mm)
- Insulation installed by creeping roof or roofing from inside - between and under chevron (45 à 150 mm sous chevron uniquement)
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
 Plant(s) Saint Avold - France (57)
 Isolant semi-rigide de 45 à 150  mm
 Certified thermal conductivity λD = 0.038 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
45 mm 1.20
50 mm 1.30
55 mm 1.45
60 mm 1.60
65 mm 1.70
70 mm 1.85
75 mm 2.00
80 mm 2.10
85 mm 2.25
90 mm 2.40
100 mm 2.65
110 mm 2.90
120 mm 3.20
130 mm 3.45
140 mm 3.70
150 mm 4.00
300 mm 8.00
 Euroclass(es) Euroclasse A1

 Other certified characteristics

 Thickness tolerance T3
 Thickness tolerance T1
 Short-term water absorption by partial immersion WS
 Water vapor permeability MU1
 Airflow resistance AFr 4