 Date created 2024-06-18
 Holder KINGSPAN INSULATION S.A.
Carretera C65, Km 16, Poligono Industrial el Trust
17244 CASSA DE LA SELVA
Spain
 Certificate no. 05/243/390/27
 Family Rigid polyurethane foam (PUR)
 Commercial brand(s) (products)
Products Purposes
Panel PIR AK - Insulation installed in pitched roof from inside - between and under chevron
- Counter plaster wallboard
- Plaster tile counter-partition
- Insulation supporting loose-laid roof waterproofing covering under heavy protection
- Counter-partition in masonry of small elements
Panel PIR 5C - Inverted insultation for terrace roof
 Plant(s) Cassà de la Selva - Espagne
 Certified thermal conductivity λD = 0.022 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
25 mm 1.15
30 mm 1.35
40 mm 1.85
50 mm 2.30
55 mm 2.55
60 mm 2.75
70 mm 3.25
80 mm 3.70
90 mm 4.15
97 mm 4.50
100 mm 4.65
102 mm 4.70
110 mm 5.10
113 mm 5.25
120 mm 5.55
130 mm 6.00
135 mm 6.25
140 mm 6.50
144 mm 6.65
147 mm 6.80
150 mm 6.95
155 mm 7.20
160 mm 7.40
All resistances
 Specifications for floor applications
Thicknesses
mm
Classification
from 25 to 120  mm SC1 a2 Ch
 ISOLE classification
Thickness
mm
I S O L E
from 25 to 120  mm 5 2 3 2 4
Puce Critical compressive strength
Thickness
mm
Rcs
(≥ kPa)
ds mini
(%)
ds maxi
(%)
Modulus of elasticity in use
(≥ MPa)
from 40 to 160  mm 130 1.3 1.6 5.40
 Euroclass(es) Euroclasse F
 Other certified characteristics
Characteristic Value
Thickness tolerance T2
Compressive stress ((de 25 à 40 mm)) CS(10/Y)175
Compressive stress ((de 50 à 160 mm)) CS(10/Y)200
Dimensional stability under defined temperature and humidity conditions DS(70,90)3
Long-term water absorption by total immersion WL(T)1