Back to the last certificates list

 Date created 2025-01-08
 Holder JACKON INSULATION GmbH
Ritzlebener Strasse 1
D-39619 ARENDSEE
Germany
 Certificate no. 07/074/463/19
 Family Extruded polystyrene (XPS)
 Commercial brand(s) (products)
Products Purposes
JACKODUR KF 500 Standard - Insulation under sealed tile (épaisseur de 40 à 100 mm panneau de 1500 mm max)
- Insulation under paving on median - Single-family home (épaisseur 40 mm minimum)
- Insulation under paving on land - Other than single-family dwelling (épaisseur de 40 mm à 200 mm)
- Thermal insulation from the exterior of the buried walls with waterproofing (épaisseur de 50 à 240 mm)
- Insulation between wood floor joists
- Insulation on wood floor joists (épaisseur de 40 à 100 mm)
- Insulation under ventilated wooden cladding
- Double masonry wall
- Insulation installed in pinched roof from inside - between and under rafter
- Insulation on suspended ceilings
- Cloth insulation
- Cloth insulation
- Flat roof insulation - inverted flat roof insulation accessible to vehicles (épaisseur de 40 à 180mm)
- Distributing or separating partitions between rooms
- Insulation under screed or floating slab or sealed tile under shaped cement mortar (épaisseur de 40 à 100 mm panneau de 1500 mm max)
- Isolation sous dallage sur terre-plein - autres que maison individuelle - Cas particulier du §5.3.4 du DTU 13.3 P1-1-1. (épaisseur 40 mm minimum)
- Thermal insulation of refrigerated buildings and premises with regulated atmosphere at positive temperature (épaisseur de 40 mm à 200 mm)
- Thermal insulation of refrigerated buildings and premises with regulated atmosphere at negative temperature (épaisseur de 40 mm à 200 mm)
DOMODUR KF 500 Standard - Insulation under sealed tile (épaisseur de 40 à 100 mm panneau de 1500 mm max)
- Insulation under paving on median - Single-family home (épaisseur 40 mm minimum)
- Insulation under paving on land - Other than single-family dwelling (épaisseur de 40 à 200 mm)
- Thermal insulation from the exterior of the buried walls with waterproofing (épaisseur de 50 à 240 mm)
- Insulation between wood floor joists
- Insulation on wood floor joists (épaisseur de 40 à 100 mm)
- Insulation under ventilated wooden cladding
- Double masonry wall
- Insulation installed in pinched roof from inside - between and under rafter
- Insulation on suspended ceilings
- Cloth insulation
- Cloth insulation
- Distributing or separating partitions between rooms
- Insulation under screed or floating slab or sealed tile under shaped cement mortar (épaisseur de 40 à 100 mm panneau de 1500 mm max)
- Isolation sous dallage sur terre-plein - autres que maison individuelle - Cas particulier du §5.3.4 du DTU 13.3 P1-1-1. (épaisseur 40 mm minimum)
- Thermal insulation of refrigerated buildings and premises with regulated atmosphere at positive temperature (épaisseur de 40 mm à 200 mm)
- Thermal insulation of refrigerated buildings and premises with regulated atmosphere at negative temperature (épaisseur de 40 mm à 200 mm)
 Plant(s) Arendsee - Allemagne
Olen - Belgique
 Certified thermal conductivity
Thicknesses
mm
Thermal conductivity
λD W/(m.K)
from 40 to 60  mm 0.034 W/(m.K)
from 70 to 240  mm 0.035 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
40 mm 1.15
50 mm 1.45
60 mm 1.75
70 mm 2.00
80 mm 2.25
90 mm 2.55
100 mm 2.85
110 mm 3.10
120 mm 3.40
130 mm 3.70
140 mm 4.00
150 mm 4.25
160 mm 4.55
170 mm 4.85
180 mm 5.10
200 mm 5.70
210 mm 6.00
220 mm 6.25
230 mm 6.55
240 mm 6.85
All resistances
 Specifications for floor applications
Thicknesses
mm
Classification
from 40 to 60  mm SC1 a2 Ch
from 70 to 100  mm SC1 a4 Ch
 ISOLE classification
Thickness
mm
I S O L E
from 40 to 100  mm 5 1 3 4 3
from 110 to 180  mm 3 1 3 4 3
from 200 to 240  mm 3 1 3 4 4
Puce Critical compressive strength
Thickness
mm
Rcs
(≥ kPa)
ds mini
(%)
ds maxi
(%)
Modulus of elasticity in use
(≥ MPa)
from 40 to 240  mm 235 0.9 1.9 10.10
 Euroclass(es) Euroclasse E
 Other certified characteristics
Characteristic Value
Thickness tolerance T1
Dimensional stability under defined temperature and humidity conditions DS(70,90)
Deformation under defined compressive load and temperature conditions DLT(2)5
Compressive stress CS(10\Y)500
Compressive creep CC(2/1,5/50)180
Freeze/thaw resistance FTCD1
Water absorption by diffusion (50 à 60 mm) WD(V)3
Water absorption by diffusion (70 à 180 mm) WD(V)2
Water absorption by diffusion (200 à 240 mm) WD(V)1
Traction perpendicular to the surfaces (100 à 240 mm) TR200
Water vapor permeability MU50
Long-term water absorption by total immersion WL(T)0,7