Date created |
2021-01-01 |
Holder |
URSA France SAS
Maille Nord III 7 Porte de Neuilly
93160 NOISY LE GRAND
France |
Certificate no. |
07/083/488/15 |
Family |
Extruded polystyrene (XPS) |
Commercial brand(s) (products) |
Products |
Purposes |
URSA XPS P HR |
- Insulation under screed or floating slab or sealed tile - Insulation between wood floor joists - Insulation on wood floor joists - Counter plaster wallboard - Against masonry wall or plaster tiles - Double masonry wall - Wood frame walls - Insulation installed by creeping roof or roofing from inside - between and under chevron |
URSA XPS P DUOPROTECT |
- Insulation under screed or floating slab or sealed tile - Insulation between wood floor joists - Insulation on wood floor joists - Counter plaster wallboard - Against masonry wall or plaster tiles - Double masonry wall - Wood frame walls - Insulation installed by creeping roof or roofing from inside - between and under chevron |
URSA XPS DUODRAIN P HR |
- Insulation under screed or floating slab or sealed tile - Insulation between wood floor joists - Insulation on wood floor joists - Counter plaster wallboard - Against masonry wall or plaster tiles - Double masonry wall - Wood frame walls - Insulation installed by creeping roof or roofing from inside - between and under chevron |
|
Plant(s) |
Saint Avold
- France (57)
|
Certified thermal conductivity |
λD = 0.029 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
30 mm
|
1.00 |
35 mm
|
1.20 |
40 mm
|
1.35 |
45 mm
|
1.55 |
50 mm
|
1.70 |
55 mm
|
1.90 |
60 mm
|
2.05 |
65 mm
|
2.20 |
70 mm
|
2.40 |
75 mm
|
2.55 |
80 mm
|
2.75 |
85 mm
|
2.90 |
90 mm
|
3.10 |
95 mm
|
3.25 |
100 mm
|
3.45 |
105 mm
|
3.60 |
110 mm
|
3.80 |
115 mm
|
3.95 |
120 mm
|
4.15 |
All resistances
Less resistances
|
|
Specifications for floor applications |
Thicknesses
mm
|
Classification |
from 30 to 120 mm
|
SC1 a4 Ch |
|
ISOLE classification |
Thickness
mm
|
I
|
S
|
O
|
L
|
E
|
from 30 to 55 mm
|
5 |
1 |
3 |
4 |
3 |
from 60 to 120 mm
|
5 |
1 |
3 |
4 |
4 |
|
Euroclass(es) |
Euroclasse E |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T1 |
Compressive stress |
CS(10/Y)300 |
Dimensional stability under defined temperature and humidity conditions |
DS (70,90) |
Deformation under defined compressive load and temperature conditions |
DLT(2)5 |
Short-term water absorption by total immersion |
WL(T)0,7 |
Long-term water absorption by diffusion |
WD(V)3 |
Freeze/thaw resistance |
FTCD1 |
|