Back to the last certificates list

 Date created 2024-05-20
 Holder URSA France SAS
Maille Nord III
7 Porte de Neuilly
93160 NOISY LE GRAND
France
 Certificate no. 08/083/510/18
 Family Glass wool (MW)
 Commercial brand(s) (products)
Products Purposes
P-Essentia 35 QN - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
P-Comble Aménagé 35 Nu - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
P-URSA THERMOCOUSTIC 35 QN - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
P-URSA Home 35 QN - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
P-LAINE VERRE 35 QN - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
P-HOMETEC 35 MOB - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
P-HOMETEC 35 - Attic insulation by panels or rolls of manufactured mineral wool
- Insulation between wood floor joists
- Counter-partition in masonry of small elements
- Plaster tile counter-partition
- Insulation under ventilated wooden cladding
- Insulation for walls covered with thin stone plates
- Double masonry wall
- Wood frame walls
- Double-skin metal cladding - Tray Cavity
- Insulation installed in pinched roof from inside - between and under rafter
- Cover insulation in ribbed plates from coated steel sheets
- Insulation on suspended ceilings
- Distributing or separating partitions between rooms
- Double skin metal cladding - between spacer
 Plant(s) Saint Avold - France (57)
 Isolant semi-rigide de 60 à 265  mm
 Certified thermal conductivity λD = 0.035 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
60 mm 1.70
70 mm 2.00
80 mm 2.25
90 mm 2.55
100 mm 2.85
110 mm 3.10
120 mm 3.40
130 mm 3.70
140 mm 4.00
150 mm 4.25
151 mm 4.30
155 mm 4.40
160 mm 4.55
170 mm 4.85
180 mm 5.10
190 mm 5.40
200 mm 5.70
210 mm 6.00
220 mm 6.25
225 mm 6.40
230 mm 6.55
235 mm 6.70
240 mm 6.85
245 mm 7.00
250 mm 7.10
255 mm 7.25
260 mm 7.40
265 mm 7.55
All resistances
 Euroclass(es) Euroclasse A1
 Other certified characteristics
Characteristic Value
Thickness tolerance T2
Water vapor permeability MU1
Short-term water absorption by partial immersion (de 60 à 210 mm) WS
Airflow resistance AFr5