Date created |
2024-04-05 |
Holder |
KNAUF
Zone d'Activité Rue Principale
68600 WOLFGANTZEN
France |
Certificate no. |
10/007/678/25 |
Family |
Rigid polyurethane foam (PUR) |
Commercial brand(s) (products) |
Products |
Purposes |
KNAUF Thane Sol |
- Insulation under sealed tile (jusqu'à 160mm - Panneaux de 1500mm max) - Insulation under paving on median - Single-family home (de 24 mm à 160 mm) - Insulation under paving on land - Other than single-family dwelling (jusqu'à 110mm) - Insulation between wood floor joists - Insulation on wood floor joists (de 24 mm à 160 mm) - Insulation installed in pitched roof from inside - between and under chevron (Epaisseurs max 80mm sous chevron) - Insulation on suspended ceilings - Insulation under screed or floating slab or sealed tile under shaped cement mortar (jusqu’à 160 mm - Panneaux de 1500mm max) - Isolation sous dallage sur terre-plein - autres que maison individuelle - Cas particulier du §5.3.4 du DTU 13.3 P1-1-1. (épaisseur maxi sous dallage 160 mm en 1 couche) - Thermal insulation of refrigerated buildings and premises with regulated atmosphere at positive temperature (épaisseur maxi sous dallage 110 mm en 1 couche) |
KNAUF Thane PrimoDalle |
- Insulation under paving on median - Single-family home (de 24 mm à 160 mm) - Insulation under paving on land - Other than single-family dwelling (Jusqu'à 110mm) - Isolation sous dallage sur terre-plein - autres que maison individuelle - Cas particulier du §5.3.4 du DTU 13.3 P1-1-1. (épaisseur maxi sous dallage 160 mm en 1 couche) - Thermal insulation of refrigerated buildings and premises with regulated atmosphere at positive temperature (épaisseur maxi sous dallage 110 mm en 1 couche) - Insulation under screed or floating slab or sealed tile under shaped cement mortar (Jusqu'à 160mm - Panneau de 1500 mm max) |
KNAUF Thane Mur-B2i |
- Double masonry wall - Insulation Primer for Lining Complex (Jusqu'à 100mm - Plage d'épaisseur selon le DTU 25.42 P1-2) |
KNAUF Thane Mur RB2 |
- Counter plaster wallboard - Counter-partition in masonry of small elements - Plaster tile counter-partition |
|
Plant(s) |
Auxerre
- France (89)
|
Certified thermal conductivity |
Thicknesses
mm
|
Thermal conductivity
λD W/(m.K)
|
from 24 to 39 mm
|
0.023 W/(m.K) |
from 40 to 160 mm
|
0.022 W/(m.K) |
|
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
24 mm
|
1.05 |
30 mm
|
1.35 |
33 mm
|
1.45 |
40 mm
|
1.85 |
48 mm
|
2.20 |
52 mm
|
2.40 |
56 mm
|
2.60 |
61 mm
|
2.80 |
68 mm
|
3.15 |
75 mm
|
3.45 |
80 mm
|
3.70 |
90 mm
|
4.15 |
95 mm
|
4.40 |
100 mm
|
4.65 |
110 mm
|
5.10 |
120 mm
|
5.55 |
130 mm
|
6.00 |
140 mm
|
6.50 |
151 mm
|
7.00 |
160 mm
|
7.40 |
All resistances
Less resistances
|
|
Specifications for floor applications |
Thicknesses
mm
|
Classification |
from 24 to 160 mm
|
SC1 a2 Ch |
|
ISOLE classification |
Thickness
mm
|
I
|
S
|
O
|
L
|
E
|
from 24 to 100 mm
|
5 |
2 |
3 |
3 |
4 |
from 110 to 120 mm
|
5 |
1 |
3 |
3 |
4 |
from 130 to 160 mm
|
5 |
1 |
3 |
3 |
4 |
|
Critical compressive strength |
Thickness
mm
|
Rcs (≥ kPa) |
ds mini (%) |
ds maxi (%) |
Modulus of elasticity in use
(≥ MPa)
|
from 24 to 80 mm
|
105 |
1.0 |
1.8 |
4.50 |
from 90 to 160 mm
|
120 |
1.0 |
1.6 |
5.54 |
|
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T2 |
Water vapor permeability |
Z 45 à 200 |
Compressive stress |
CS(10/Y)150 |
Short-term water absorption by partial immersion |
WS(P) 0.2 |
|