Date created |
2024-05-07 |
Holder |
PLADUR GYPSUM S.A.U.
Ctra ANDALUCIA Km 30,2
28343 VALDEMORO
Spain |
Certificate no. |
16/174/1234/7 |
Family |
Expanded polystyrene (EPS) |
Commercial brand(s) (products) |
Products |
Purposes |
PLADUR ISOPOP® 32 |
- Insulation Primer for Lining Complex - Counter-partition in masonry of small elements - Plaster tile counter-partition - Distributing or separating partitions between rooms - Insulation installed in pinched roof from inside - between and under rafter |
|
Plant(s) |
Gelsa
- Espagne
|
Certified thermal conductivity |
λD = 0.032 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
20 mm
|
0.60 |
30 mm
|
0.90 |
40 mm
|
1.25 |
60 mm
|
1.85 |
80 mm
|
2.50 |
100 mm
|
3.10 |
120 mm
|
3.75 |
140 mm
|
4.35 |
160 mm
|
5.00 |
180 mm
|
5.60 |
200 mm
|
6.25 |
All resistances
Less resistances
|
|
ISOLE classification |
Thickness
mm
|
I
|
S
|
O
|
L
|
E
|
from 20 to 40 mm
|
1 |
2 |
2 |
3(50) |
2 |
from 60 to 200 mm
|
1 |
2 |
2 |
3(50) |
3 |
|
Euroclass(es) |
Euroclasse E |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T(2) |
Water vapor permeability |
MU 20-40 |
Traction perpendicular to the surfaces |
TR50 |
Length tolerance |
L(3) |
Width tolerance |
W(3) |
Squareness tolerance |
S(2) |
Flatness tolerance |
P(5) |
Dimensional stability under constant normal laboratory conditions |
DS(N)2 |
Dimensional stability under defined temperature and humidity conditions |
DS(23,90) |
Bend resistance |
BS50 |
|