Date created |
2025-01-08 |
Holder |
JACKON INSULATION GmbH
Ritzlebener Strasse 1
D-39619 ARENDSEE
Germany |
Certificate no. |
19/074/1353/7 |
Family |
Extruded polystyrene (XPS) |
Commercial brand(s) (products) |
Products |
Purposes |
JACKODUR Plus 300 Standard |
- Insulation under sealed tile (de 40 à 300 mm - panneau de 1500 mm max) - Insulation under paving on median - Single-family home (de 50 à 320 mm) - Insulation under paving on land - Other than single-family dwelling (de 50 à 140 mm) - Thermal insulation from the exterior of the buried walls with waterproofing - Insulation between wood floor joists - Insulation on wood floor joists (de 40 à 300 mm) - Counter plaster wallboard - Against masonry wall or plaster tiles - Insulation under ventilated wooden cladding - Double masonry wall - Insulation installed in pinched roof from inside - between and under rafter - Flat roof insulation - Inverted flat roof insulation (de 40 à 320 mm en 1 lit) - Insulation under screed or floating slab or sealed tile under shaped cement mortar (de 40 à 300 mm - panneau de 1500 mm max) - Isolation sous dallage sur terre-plein - autres que maison individuelle - Cas particulier du §5.3.4 du DTU 13.3 P1-1-1. (de 50 à 230 mm) - Thermal insulation of refrigerated buildings and premises with regulated atmosphere at positive temperature (de 50 à 140 mm) - Thermal insulation of refrigerated buildings and premises with regulated atmosphere at negative temperature (de 50 à 140 mm) |
|
Plant(s) |
Arendsee
- Allemagne
|
Certified thermal conductivity |
λD = 0.027 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
40 mm
|
1.45 |
50 mm
|
1.85 |
60 mm
|
2.20 |
70 mm
|
2.55 |
80 mm
|
2.95 |
90 mm
|
3.30 |
100 mm
|
3.70 |
110 mm
|
4.05 |
120 mm
|
4.40 |
130 mm
|
4.80 |
140 mm
|
5.15 |
150 mm
|
5.55 |
160 mm
|
5.90 |
170 mm
|
6.25 |
180 mm
|
6.65 |
190 mm
|
7.00 |
200 mm
|
7.40 |
210 mm
|
7.75 |
220 mm
|
8.10 |
230 mm
|
8.50 |
240 mm
|
8.85 |
250 mm
|
9.25 |
260 mm
|
9.60 |
270 mm
|
10.00 |
280 mm
|
10.35 |
290 mm
|
10.70 |
300 mm
|
11.10 |
310 mm
|
11.45 |
320 mm
|
11.85 |
All resistances
Less resistances
|
|
Specifications for floor applications |
Thicknesses
mm
|
Classification |
from 40 to 300 mm
|
SC1 a2 Ch |
|
Critical compressive strength |
Thickness
mm
|
Rcs (≥ kPa) |
ds mini (%) |
ds maxi (%) |
Modulus of elasticity in use
(≥ MPa)
|
from 50 to 320 mm
|
145 |
0.7 |
1.8 |
7.00 |
|
Euroclass(es) |
Euroclasse E |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T1 |
Dimensional stability under defined temperature and humidity conditions |
DS (70,90) |
Water vapor permeability |
MU50 |
Freeze/thaw resistance |
FTCD1 |
Compressive stress |
CS(10\Y)300 |
Traction perpendicular to the surfaces (90 à 320 mm) |
TR200 |
Deformation under defined compressive load and temperature conditions |
DLT(2)5 |
Long-term water absorption by total immersion |
WL(T)0.7 |
Water absorption by diffusion (190-320mm) |
WD(V)1 |
Water absorption by diffusion (90-180mm) |
WD(V)2 |
Water absorption by diffusion (40-80mm) |
WD(V)3 |
|