Date created |
2024-10-25 |
Holder |
PRB
16 rue de la Tour La Mothe Achard
85150 LES ACHARDS
France |
Certificate no. |
19/201/1365/4 |
Family |
Expanded polystyrene (EPS) |
Commercial brand(s) (products) |
Products |
Purposes |
PRB.SOL.TH34 |
- Insulation under sealed tile (de 20 à 300 mm - panneau de 1500 mm max) - Insulation under paving on median - Single-family home (de 40 à 300 mm) - Insulation under paving on land - Other than single-family dwelling (de 40 à 70 mm) - Insulation between wood floor joists - Insulation on wood floor joists (de 20 à 300 mm) - Insulation under screed or floating slab or sealed tile under shaped cement mortar (de 20 à 300 mm - panneau de 1500 mm max) |
PRB.THERMI.TOIT.TH34 |
- Insulation supporting loose-laid roof waterproofing covering under heavy protection (de 40 à 300 mm) |
PRB.TH34 |
- Insulation under sealed tile (de 20 à 300 mm - panneau de 1500 mm max) - Insulation under paving on median - Single-family home (de 40 à 300 mm) - Insulation under paving on land - Other than single-family dwelling (de 40 à 70 mm) - Insulation between wood floor joists - Insulation on wood floor joists (de 20 à 300 mm) - Insulation under screed or floating slab or sealed tile under shaped cement mortar (de 20 à 300 mm - panneau de 1500 mm max) |
PRB.EPS150 |
- Insulation under sealed tile (de 20 à 300 mm - panneau de 1500 mm max) - Insulation under paving on median - Single-family home (de 40 à 300 mm) - Insulation under paving on land - Other than single-family dwelling (de 40 à 70 mm) - Insulation between wood floor joists - Insulation on wood floor joists (de 20 à 300 mm) - Insulation under screed or floating slab or sealed tile under shaped cement mortar (de 20 à 300 mm - panneau de 1500 mm max) |
|
Plant(s) |
La Mothe Achard
- France (85)
|
Certified thermal conductivity |
λD = 0.034 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
20 mm
|
0.55 |
30 mm
|
0.85 |
40 mm
|
1.15 |
50 mm
|
1.45 |
60 mm
|
1.75 |
70 mm
|
2.05 |
80 mm
|
2.35 |
90 mm
|
2.65 |
100 mm
|
2.95 |
110 mm
|
3.25 |
120 mm
|
3.55 |
130 mm
|
3.80 |
140 mm
|
4.10 |
150 mm
|
4.40 |
160 mm
|
4.70 |
170 mm
|
5.00 |
180 mm
|
5.30 |
190 mm
|
5.60 |
200 mm
|
5.90 |
210 mm
|
6.20 |
220 mm
|
6.50 |
230 mm
|
6.80 |
240 mm
|
7.10 |
250 mm
|
7.35 |
260 mm
|
7.65 |
270 mm
|
7.95 |
280 mm
|
8.25 |
290 mm
|
8.55 |
300 mm
|
8.85 |
All resistances
Less resistances
|
|
Specifications for floor applications |
Thicknesses
mm
|
Classification |
from 20 to 300 mm
|
SC1 a4 Ch |
|
ISOLE classification |
Thickness
mm
|
I
|
S
|
O
|
L
|
E
|
from 20 to 50 mm
|
5 |
1 |
3 |
4 |
2 |
from 60 to 200 mm
|
5 |
1 |
3 |
4 |
3 |
from 210 to 300 mm
|
5 |
1 |
3 |
4 |
4 |
|
Critical compressive strength |
Thickness
mm
|
Rcs (≥ kPa) |
ds mini (%) |
ds maxi (%) |
Modulus of elasticity in use
(≥ MPa)
|
from 40 to 300 mm
|
75 |
1.0 |
1.5 |
3.60 |
|
Euroclass(es) |
Euroclasse E |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T(2) |
Compressive stress |
CS(10\Y)150 |
Traction perpendicular to the surfaces |
TR180 |
Water vapor permeability |
MU(30-70) |
|