Date created |
2025-03-18 |
Holder |
SAINT GOBAIN ISOVER
Tour Saint-Gobain 12 place de l'Iris
92400 Courbevoie
France |
Certificate no. |
02/018/100/34 |
Family |
Glass wool (MW) |
Commercial brand(s) (products) |
Products |
Purposes |
GR 32 REVETU KRAFT |
- Counter plaster wallboard - Counter-partition in masonry of small elements - Double masonry wall - Wood frame walls - Plaster tile counter-partition - Insulation installed in pinched roof from inside - between and under rafter |
GR 32 ROULE REVETU KRAFT |
- Counter plaster wallboard - Counter-partition in masonry of small elements - Double masonry wall - Wood frame walls - Plaster tile counter-partition - Insulation installed in pinched roof from inside - between and under rafter |
GR 32 ROULE REVETU KRAFT ALU |
- Counter plaster wallboard - Counter-partition in masonry of small elements - Double masonry wall - Wood frame walls - Plaster tile counter-partition |
|
Plant(s) |
Chemillé
- France (49)
Orange
- France (84)
Speyer
- Allemagne
|
Isolant semi-rigide |
de 45 à 180 mm
|
Certified thermal conductivity |
λD = 0.032 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
45 mm
|
1.40 |
60 mm
|
1.85 |
65 mm
|
2.05 |
70 mm
|
2.20 |
75 mm
|
2.35 |
80 mm
|
2.50 |
85 mm
|
2.65 |
90 mm
|
2.80 |
95 mm
|
2.95 |
100 mm
|
3.15 |
120 mm
|
3.75 |
130 mm
|
4.05 |
140 mm
|
4.35 |
150 mm
|
4.65 |
151 mm
|
4.70 |
160 mm
|
5.00 |
180 mm
|
5.60 |
All resistances
Less resistances
|
|
Euroclass(es) |
Euroclasse F |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T3 |
Short-term water absorption by partial immersion |
WS |
Airflow resistance |
AFr15 |
Mass Thermal Capacity |
840 J/(Kg.K) |
Water vapor permeability (GR 32 ROULE REVETU KRAFT et GR 32 ROULE KRAFT) |
Z0.1 |
|