Date created |
2025-05-16 |
|
Holder |
PAROC
Energiakuja 3 P.O. Box 240
FI-00181 HELSINKI
Finland |
|
Certificate no. |
19/245/1377/3 |
|
Family |
Rock wool (MW) |
|
Commercial brand(s) (products) |
| Products |
Purposes |
|
FAL 1cc |
|
|
Sto-Speedlamelle Typ II plus |
|
|
|
Plant(s) |
Trzemeszno
- Pologne
|
|
Certified thermal conductivity |
λD = 0.039 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
|
40 mm
|
1.00 |
|
50 mm
|
1.25 |
|
60 mm
|
1.50 |
|
70 mm
|
1.75 |
|
80 mm
|
2.05 |
|
90 mm
|
2.30 |
|
100 mm
|
2.55 |
|
110 mm
|
2.80 |
|
120 mm
|
3.05 |
|
130 mm
|
3.30 |
|
140 mm
|
3.55 |
|
150 mm
|
3.80 |
|
160 mm
|
4.10 |
|
170 mm
|
4.35 |
|
180 mm
|
4.60 |
|
190 mm
|
4.85 |
|
200 mm
|
5.10 |
|
210 mm
|
5.35 |
|
220 mm
|
5.60 |
|
230 mm
|
5.85 |
|
240 mm
|
6.15 |
|
250 mm
|
6.40 |
|
260 mm
|
6.65 |
|
270 mm
|
6.90 |
|
280 mm
|
7.15 |
|
290 mm
|
7.40 |
|
300 mm
|
7.65 |
|
All resistances
Less resistances
|
|
|
Euroclass(es) |
Euroclasse A1 |
|
Other certified characteristics |
|
Characteristic |
Value |
|
Thickness tolerance |
T5 |
|
Compressive stress |
CS(Y)40 |
|
Traction perpendicular to the surfaces |
TR80 |
|
Dimensional stability under defined temperature and humidity conditions |
DS(70,90) |
|
Short-term water absorption by partial immersion |
WS |
|
Long-term water absorption by partial immersion |
WL(P) |
|
Water vapor permeability |
MU1 |
|