Date created |
2024-01-01 |
Holder |
SAINT GOBAIN ISOVER
Tour Saint-Gobain 12 place de l'Iris
92400 Courbevoie
France |
Certificate no. |
02/018/118/17 |
Family |
Rock wool (MW) |
Commercial brand(s) (products) |
Products |
Purposes |
PANOTOIT FIBAC 2 |
|
PANOTOIT FIBAC 2 VV |
|
PRIMITIF PROTECT LR B |
|
PROTECT LR B |
|
JOINT PROTECT LR B |
|
|
Plant(s) |
Genouillac
- France (23)
|
Certified thermal conductivity |
Thicknesses
mm
|
Thermal conductivity
λD W/(m.K)
|
from 40 to 95 mm
|
0.038 W/(m.K) |
from 100 to 160 mm
|
0.039 W/(m.K) |
|
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
40 mm
|
1.05 |
45 mm
|
1.15 |
50 mm
|
1.30 |
55 mm
|
1.40 |
60 mm
|
1.55 |
65 mm
|
1.70 |
70 mm
|
1.80 |
75 mm
|
1.95 |
80 mm
|
2.10 |
85 mm
|
2.20 |
90 mm
|
2.35 |
95 mm
|
2.50 |
100 mm
|
2.55 |
105 mm
|
2.65 |
110 mm
|
2.80 |
115 mm
|
2.90 |
120 mm
|
3.05 |
125 mm
|
3.20 |
130 mm
|
3.30 |
135 mm
|
3.45 |
140 mm
|
3.55 |
145 mm
|
3.70 |
150 mm
|
3.80 |
155 mm
|
3.95 |
160 mm
|
4.10 |
All resistances
Less resistances
|
|
Euroclass(es) |
Euroclasse A1 |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T5 |
Short-term water absorption by partial immersion |
WS |
Dimensional stability under defined temperature and humidity conditions |
DS(70,90) |
Compressive strength at 10% deformation |
CS(10)50 |
Traction perpendicular to the surfaces |
TR10 |
Airflow resistance |
AFr 70 |
Water vapor permeability |
MU1 |
|