Back to the last certificates list

 Date created 2024-01-01
 Holder JACKON INSULATION GmbH
Ritzlebener Strasse 1
D-39619 ARENDSEE
Germany
 Certificate no. 03/074/265/14
 Family Extruded polystyrene (XPS)
 Commercial brand(s) (products)
Products Purposes
JACKODUR KF 300 GEFINIERT - Counter plaster wallboard
- Against masonry wall or plaster tiles
- Insulation under ventilated wooden cladding
- Cloth insulation (épaisseur de 30 à 180 mm)
- Insulation installed in pinched roof from inside - between and under rafter
- Insulation on suspended ceilings
- Cloth insulation (épaisseur de 30 à 180 mm)
- Distributing or separating partitions between rooms
DOMODUR KF 300 GEFINIERT - Counter plaster wallboard
- Against masonry wall or plaster tiles
- Insulation under ventilated wooden cladding
- Cloth insulation (épaisseur de 30 à 180 mm)
- Insulation installed in pinched roof from inside - between and under rafter
- Insulation on suspended ceilings
- Cloth insulation (épaisseur de 30 à 180 mm)
- Distributing or separating partitions between rooms
 Plant(s) Arendsee - Allemagne
Olen - Belgique
 Certified thermal conductivity
Thicknesses
mm
Thermal conductivity
λD W/(m.K)
from 15 to 60  mm 0.034 W/(m.K)
from 80 to 180  mm 0.035 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
15 mm 0.40
20 mm 0.55
25 mm 0.70
30 mm 0.85
40 mm 1.15
50 mm 1.45
60 mm 1.75
80 mm 2.25
90 mm 2.55
100 mm 2.85
110 mm 3.10
120 mm 3.40
130 mm 3.70
140 mm 4.00
150 mm 4.25
160 mm 4.55
170 mm 4.85
180 mm 5.10
All resistances
 Specifications for floor applications
Thicknesses
mm
Classification
from 15 to 80  mm SC1 a3 Ch
 ISOLE classification
Thickness
mm
I S O L E
from 15 to 80  mm 5 1 3 4 3
from 90 to 180  mm 4 1 3 4 3
 Euroclass(es) Euroclasse E
 Other certified characteristics
Characteristic Value
Thickness tolerance T1
Compressive stress (30 à180 mm) CS(10\Y)300
Compressive stress (15 à 20 mm) CS(10\Y)200
Dimensional stability under defined temperature and humidity conditions DS(70,90)
Deformation under defined compressive load and temperature conditions DLT(2)5
Traction perpendicular to the surfaces TR200
Water vapor permeability MU50