Back to the last certificates list

 Date created 2024-01-01
 Holder KNAUF
Zone d'Activité
Rue Principale
68600 WOLFGANTZEN
France
 Certificate no. 23/007/1628/1
 Family Expanded polystyrene (EPS)
 Commercial brand(s) (products)
Products Purposes
KNAUF XTherm Sol Th31 - Insulation under sealed tile (Jusqu’à 200 mm – Panneaux 1500 mm max)
- Insulation under screed or floating slab or sealed tile under shaped cement mortar (Jusqu’à 200 mm – Panneaux 1500 mm max)
 Plant(s) Colomiers - France (31)
Rousset - France (13)
 Certified thermal conductivity λD = 0.031 W/(m.K)
Puce Certified thermal resistance
Thicknesses
mm
Thermal resistances
m².K/W
20 mm 0.60
25 mm 0.80
30 mm 0.95
35 mm 1.10
36 mm 1.15
40 mm 1.25
42 mm 1.35
45 mm 1.45
50 mm 1.60
55 mm 1.75
60 mm 1.90
65 mm 2.05
70 mm 2.25
72 mm 2.30
75 mm 2.40
80 mm 2.55
81 mm 2.60
85 mm 2.70
90 mm 2.90
92 mm 2.95
95 mm 3.05
100 mm 3.20
105 mm 3.35
110 mm 3.50
115 mm 3.70
120 mm 3.85
125 mm 4.00
130 mm 4.15
135 mm 4.35
140 mm 4.50
145 mm 4.65
150 mm 4.80
155 mm 5.00
160 mm 5.15
165 mm 5.30
170 mm 5.45
175 mm 5.60
180 mm 5.80
186 mm 6.00
190 mm 6.10
195 mm 6.25
200 mm 6.45
All resistances
 Specifications for floor applications
Thicknesses
mm
Classification
from 20 to 200  mm SC1 a2 Ch
 ISOLE classification
Thickness
mm
I S O L E
from 20 to 45  mm 5 1 2 2 2
from 50 to 200  mm 5 1 2 2 3
 Other certified characteristics
Characteristic Value
Thickness tolerance T(2)
Water vapor permeability MU 30 à 70