Date created |
2024-01-01 |
Holder |
KINGSPAN INSULATION S.A.
Carretera C65, Km 16, Poligono Industrial el Trust
17244 CASSA DE LA SELVA
Spain |
Certificate no. |
23/243/1626/1 |
Family |
Rigid polyisocyanurate foam (PIR) |
Commercial brand(s) (products) |
Products |
Purposes |
Therma TP 11 SP |
|
|
Plant(s) |
Cassà de la Selva
- Espagne
|
Certified thermal conductivity |
λD = 0.022 W/(m.K) |
Certified thermal resistance |
Thicknesses
mm
|
Thermal resistances
m².K/W
|
60 mm
|
2.75 |
65 mm
|
3.00 |
70 mm
|
3.25 |
75 mm
|
3.45 |
80 mm
|
3.70 |
85 mm
|
3.95 |
90 mm
|
4.15 |
95 mm
|
4.40 |
100 mm
|
4.65 |
105 mm
|
4.85 |
110 mm
|
5.10 |
115 mm
|
5.30 |
120 mm
|
5.55 |
122 mm
|
5.65 |
125 mm
|
5.80 |
130 mm
|
6.00 |
140 mm
|
6.50 |
150 mm
|
6.95 |
151 mm
|
7.00 |
160 mm
|
7.40 |
All resistances
Less resistances
|
|
ISOLE classification |
Thickness
mm
|
I
|
S
|
O
|
L
|
E
|
from 60 to 160 mm
|
5 |
2 |
3 |
2 |
4 |
|
Critical compressive strength |
Thickness
mm
|
Rcs (≥ kPa) |
ds mini (%) |
ds maxi (%) |
Modulus of elasticity in use
(≥ MPa)
|
from 60 to 160 mm
|
130 |
1.3 |
1.6 |
5.40 |
|
Euroclass(es) |
Euroclasse E |
Other certified characteristics |
Characteristic |
Value |
Thickness tolerance |
T2 |
Dimensional stability under defined temperature and humidity conditions |
DS(70,90)3 |
Long-term water absorption by total immersion |
WL(T)1 |
Compressive stress |
CS(10/Y)200 |
|